Availability: | |
---|---|
Quantity: | |
FH-1000(X)
BIOBASE
Product Description
Applications:
Fume Hood is used to protect lab environment and operatorduring general chemical applications .It actively protects operator frominhaling toxic vapors and dramatically reduces the risk of fire and explosion. Byinstalling proper filter, it can also protect environment.
Features:
1. UV lamp for sterilization.
2. Motorized front glass window.
3. Resistant to weak acid and alkali.
4. Adjustable air speed: 9 levels.
5. Alarm when filter working time 3500 hours.
6. With memory function in case of power-failure.
7. Back side air compensation, to avoid turbulence in work area.
8. 8° slope front ergonomics design, fatigue-free working posture.
9. Microprocessor control system, LEd display shows filter working time.
10. Transparent side glass windows maximize light and visibility inside the cabinet, providing a bright and open working environment.
Installation Notice:
Fume hood installation location should avoid facing road and site that people pass frequently, avoid placing where the windows clogged and the lighting is unsufficient, avoid placing where the entrance and the door affected, avoid placing opposite and in the corner of the wall.
a) Only applicable to indoor operation
b) Ambient temperature: 15℃~35℃
c) Relative humidity: ≤75%
d) Atmospheric pressure range: 70 kPa~106 kPa
e) Electrical parameters: consistent with the rated voltage of the Fume Hood (See
2.1.4 Technical parameters)
f) Power supply need to be grounded (Judging method: test the live wire and the neutral wire of the main socket with multimeter. The voltage between live and ground should equal to the voltage of local electrical grid, and the voltage between neutral and ground should equal to 0. Otherwise, the power supply is not grounded correctly.)
Operation Notice:
a) Make sure input voltage is correct and stable. The rated load of main power socket should be higher than cabinet consumption. Plug must be well grounded.
b) The equipment should be powered off and unplugged before doing any replacement of parts, such as UV lamp and fluorescent lamp.
c) The front window is made of explosion-proof toughened glass. In order to keep the front window clean and clear, please wipe it by wet soft cloth and keep it away from hydrofluoric acid
d) The air deflector and other internal accessories should be cleaned according to the use of the Fume Hood
e) The air duct and the blower of the Fume Hood should be cleaned and maintained regularly in a proper way
f) Fume Hood should be placed in a position where there should be no other equipment or machine within 150mm of the front window
g) Do NOT place any soft or tiny materials (such as soft tissue) on the work table during the operation to prevent breakdown of the blower causing by sucking those materials
h) The packed Fume Hood should be stored in a warehouse with relative humidity no more than 75% and temperature lower than 40℃. The warehouse should have good ventilation performance without acid, alkali or other corrosive gases
i) The maximum storage period is one year. A performance inspection should be done if the storage period exceeds one year
Parameters
Model | FH1000(X) | FH1200(X) | FH1500(X) | FH1800(X) |
External Size (W*D*H) | 1000*840*2150mm | 1200*840*2150mm | 1500*840*2150mm | 1800*840*2150mm |
Internal Size (W*D*H) | 880*730*745mm | 1080*730*745mm | 1380*730*745mm | 1680*730*745mm |
Max Opening | 520mm | |||
Work Surface Height | 750mm | |||
Blower | Built-in centrifugal blowers; Speed adjustable with 9 levels | |||
Air Velocity | 0.3~0.8m/s | |||
Noise | ≤68dB | |||
LED Lamp | 8W*1 | 12W*1 | 16W*1 | 16W*1 |
UV Lamp | Emission of 253.7 nanometers for most efficient decontamination | |||
Front Window | Motorized;5 mm toughened glass, anti-UV | |||
Material | Exterior Body: Cold-rolled steel with anti-bacteria powder coating. | |||
Work table: Chemical resistant phenolic resin | ||||
Waterproof Socket | 1 pc | 2 pcs | 2 pcs | 2 pcs |
Power Supply | AC220V±10%,50/60Hz;110V±10%, 60Hz | |||
Consumption | 400W | 400W | 500W | 500W |
Stand Accessory | Water tap; Gas tap; Water sink; Base stand, UV lamp*2, LED lamp, Socket, 4 meters exhaust duct, Active carbon filter, Foot switch | |||
Gross Weight | 230kg | 253kg | 290kg | 340kg |
Package Size(W*D*H) | 1150*1120*1680 mm | 1350*1120*1680mm | 1650*1120*1680mm | 1950*1120*1680mm |
Service
Pre-sales service:
♥24 hours online to ensure quick response to customers' inquiry or online message.
♥Guide customers to choose the best suitable machine model.
♥Offer detailed specification and competitive prices.
♥Customization available for special specification products.
♥Sample testing support. View our Factory.
After-sales service:
♥Training how to install and use the machine.
♥ available to service machinery overseas.
♥In response to customers technical problems.
♥12-month warranty for most of products.
♥Your technicians can be trained by our company.
Lead time is about 3 to 5 working days from the date of receiving payment. Please allow an extension of lead time when sales hot season.
Packing List
No. | Items | Quantity |
1 | Main body | 1 unit |
2 | Base stand | 1 set |
3 | User manual | 1 pc |
4 | Certification of quality | 1 pc |
5 | Inspection report | 1 pc |
6 | UV lamp | 1 pc |
7 | Fuse (10A) | 1 pc |
8 | Stainless steel hex cylinder head screw M10*55 Stainless steel flat washer10 Stainless steel spring washer 10 |
2 sets |
9 | PP small water sink and accessories | 1 set |
10 | Water tap | 1 pc |
11 | Gas tap | 1 pc |
12 | Exhaust duct | 1 pc |
13 | Duct clamp | 1 pc |
14 | Foot Switch | 1 pc |
15 | Power cord | 1 pc |
16 | Motor control rod | 1 pc |
17 | Allen wrench | 1 pc |